USAfixTM - Repair Guide (RG) - Master Email RG
- Check the pressure switch
 Level of Difficulty - HIGH  Estimated Completion Time - 15 minutes
TASKI - SWINGO 150

Tools Required
Tool 
Screwdriver-phillips

Parts Required


Step Procedure & Parts & Tools
1 REMOVE THE 4 SCREWS HOLDING THE HANDLE.
Screwdriver-phillips

2 LIFT THE HANDLE UP.

3 DISCONNECT THE PLUG AND REMOVE THE HANDLE FROM THE MACHINE.

4 LOCATE THE YELLOW WIRE CONNECTOR AND THE BLACK WIRE CONNECTOR ON THE PRESSURE SWITCH. PLACE VOLT METER LEADS ON EACH POST BETWEEN THE WIRE CONNECTOR AND THE SWITCH TOUCHING THE EXPOSED POST. SET THE VOLT METER TO CONTINUITY. IF THE VOLT METER BEEPS, THE PRESSURE SWITCH IS OKAY. REVERSE STEPS 1 THRU 3 TO REASSEMBLE THE MACHINE.